Fixing & compression engineering

WallMax® Accessories

WallMax® system accessories for modular cable and pipe sealing in Mexico: WE/WEC expanders, WRP/WRPC retainer plates, WPCT tools, lubricants, WSS sealing strips, and mounting sleeves. Identify each component and request engineering advisory.

Mechanical precision · Zero leak tolerance
SS AISI 316L · Galvanized · EPDM
Series-verified compatibility
Operating principle

Every component performs a critical mechanical function.

Watch installation ↗

A Multi Cable Transit (MCT) sealing system is not a loose assortment of parts—it is a tested mechanical assembly where every accessory ensures uniform compression distribution and seal integrity against fire, water, gases, and vibration.

Tested WallMax WRF assembly with frame, modules, WRP retainer plates, and WE expander
Anatomy of the assembly
01

Structural frame WRF / WMF / WRS

Defines the calibrated packing space. Anchored to the wall, deck, or bulkhead by welding, bolting, or casting into concrete.

02

Sealing modules WMR / WMC

EPDM rubber cradles featuring multicolor peel-off layers that wrap and seal tightly around every cable or pipe diameter.

03

Retainer plates WRP / WRPC

Ridged metallic retainer plates inserted between horizontal rows of modules to prevent sliding and transmit lateral compression forces.

04

Pre-compression tool WPCT

Threaded mechanical tool used to temporarily pre-compress stacked modules, creating exact vertical clearance prior to inserting the expander.

05

Compression unit WE / WEC Expander

Elastomeric mechanical expander that expands vertically when its front bolts are tightened, pressurizing the assembly for certified tightness.

06

Assembly lubricant WMLub / WMLubSil

Technical lubricant required to minimize friction when sliding modules and to seal microscopic interfaces between rubber surfaces and the frame.

04 / Assembly workflow

How WallMax® Accessories Are Installed

01 WMLub Lubricant

Lubricate contact surfaces

Apply a uniform film of WMLub lubricant to internal frame walls and elastomer module faces to eliminate assembly friction and fill surface micro-voids.

02 WRP Retainer Plates

Insert retainer plates between rows

As cable layers and WMR modules are placed, insert a WRP retainer plate over each horizontal row. Its ridges prevent modules from slipping or being pushed out during tightening.

03 WPCT Tool

Pre-compress the stack

Before installing the final expander, mount the WPCT spindle tool onto the top edge and tighten temporarily to compress the rubber stack and create the exact 60 mm clearance required.

04 WE / WEC Expander

Compress & pressurize

Remove the WPCT tool, slide the WE Expander into the cleared space, and tighten its front hex bolts alternately until achieving rated compression.

07 / Procurement & specification advisory

Data Required to Quote WallMax® Accessories

These details allow accurate hardware BOM calculation for a complete transit assembly. For loose replacement accessories, simply share the part number, material, and quantity.

1

Packing space width & height

Determines WE Expander width (120, 60, or 40 mm) and WRP retainer plate length, while overall frame height defines the number of stackable module rows.

2

System depth (60 mm vs 30 mm)

Regular systems (WRF/WMR) require 60 mm WRP retainer plates and WE expanders. Compact systems (WMC) require 30 mm WRPC retainer plates and WEC expanders.

3

Cable/pipe count & outer diameters

Specify total number of cables or pipes passing through the frame along with each exact outer diameter in millimeters.

4

Number of horizontal module rows

Engineering practice requires inserting one WRP retainer plate between every row of modules (typically rows minus one). Retainer plates must never be omitted.

5

Corrosive environment & hardware alloy

Marine, coastal, petrochemical, or tunnel applications require Stainless Steel AISI 316L hardware; dry indoor industrial sites normally specify Galvanized Steel.

6

Fixing method & flange perimeter sealing

Bolted flanged frames require WSS sealing strips or pre-punched EPDM gaskets, plus O-ring sealing washers on through-fastening bolts.

08 / Engineering criteria

Frequently Asked Questions on WallMax® Accessories

What is the difference between WMLub (natural grease) and WMLubSil (silicone)?

The official WallMax catalog distinguishes both clearly: WMLub is a natural grease developed for metallic frames (WRF, WMF, WRS, WR) and high-pressure or severe tightness applications. WMLubSil is a silicone-based grease specially formulated for glass-fiber reinforced polyamide frames (PA 6.6 GF) and the compact WM mini R series, recommended for low-pressure sealing applications up to IP65.

Why must NO WRP retainer plate ever be omitted?

WRP and WRPC retainer plates are structural components—not passive dividers. They absorb lateral force and distribute expansion pressure evenly across the modules. Their ridges interlock with the elastomer so internal pressure (up to 4 bar water / 2.67 bar gas) or axial cable pull cannot push modules out of the frame.

Does the WE expander allow future opening and re-cabling?

Yes. Unlike non-reopenable intumescent foams or rigid sealants, the WallMax WE and WEC mechanical expander is 100% reusable and reversible. Simply loosen the front bolts with a standard wrench to decompress the EPDM expander and remove or add cables and modules without damaging existing components or requiring civil work.

Which sealant or perimeter gasket should be selected for each structure?

Per the catalog's installation appendix: on bolted steel structures, pre-punched EPDM gaskets or WSS sealing strips with O-ring washers are recommended; on smooth concrete walls, use Fire Barrier Water Tight Sealant; on brick walls or gypsum/wood/sandwich panels with surface irregularities, Super Sealer No.10 Silicone Sealant is recommended with WRHFF flanged frames or SLVFWR sleeves.

Do fire and pressure certifications apply to single accessories or to the full system?

International certifications (A0/A60 under IMO FTP Code, EI 120 under EN 45545-3 / EN 13501, 4 bar water and 2.67 bar gas tightness) cover the complete properly installed system, including the WallMax® frame, modules, retainer plates, and expanders. No single component certifies these ratings in isolation.

What is included inside a WallMax WE 120 Kit?

Each WE 120 Kit (article 71 6011 0101 in Stainless Steel or 71 6013 0101 in Galvanized Steel) includes: 1 WE 120 mm Expander + 5 WRP 120 mm retainer plates + 1 WMLub 25 ml lubricant jar, consolidating all accessories needed for a standard frame under a single order code.

Specialized Technical Advisory · Mexico

Quote the WallMax® Accessory You Need.

We can help identify and quote either individual spare components or a full hardware BOM for your penetration assembly. Even if you don't know the part code, send a photo and basic measurements.

Helpful details for quoting any accessory

  • Accessory name, series, or article code; a photo is also helpful.
  • Required quantity of pieces, kits, or lubricant packs.
  • Size, capacity, material alloy, or variant if known.
  • Target frame model and aperture dimensions, where applicable.
  • Number and outer diameters of cables or pipes, where applicable.
  • Operating environment and structural mounting method, if applicable.